ED-NHR-75W-700MA-100-300-001-R1-V0 SPEC
Items | Min | Nom | Max | Unit |
Rated mains voltage | 100 | 300 | V | |
Operational mains voltage limits | 90 | 440 | V | |
Mains frequency nominal | 50/60 | Hz | ||
Input under voltage for protection | N.A | V | ||
Input over voltage for protection | 330 | V | ||
Restart voltage | 310 | V | ||
Input Power @230Vac, full load | 82 | W | ||
Input Power @100Vac, full load | N.A | W | ||
Input Power @ None Load , rated mains voltage | 0.6 | W | ||
System Efficiency @230Vac, full load | 91 | % | ||
Input Current @220Vac, full load | 440 | mA | ||
Power Factor @Input and Output performance range | 0.95 | |||
THD @Input and Output performance range | 10 | % | ||
Turn on delay time | 0.5 | S | ||
Inrush Current | 30A、210uS | A、uS |
OUTPUT PARAMETERS
Items | Min | Nom | Max | Unit |
Output Voltage (performance) | 60 | 107 | V | |
Output Voltage tolerance (only for CV) | N.A | % | ||
Output voltage ripple (only for CV) | N.A | mV | ||
Max Output Voltage @ None load | 125 | V | ||
Ouput Current (performance) | 700 | mA | ||
Output Current Tolerance (only for CC) | 8 | % | ||
Percent of the output current ripple (only for CC) | 30 | % | ||
Output performance power range | 42 | 75 | W | |
Max Output Power (Over Power protection) | 84 | W | ||
Short Circuit Protection | Yes 、 Auto recovery |
OTHER PARAMETERS
Ambient temperature (Ta) | -10 – 60℃ |
Maximum T case (Tc.max) | N.A |
Life Time & Warranty | >30000H @ Ta =60℃ ; 3 years |
Thermal Protection (Tc . limit) | 90℃、Auto recovery |
Suitable Environment (IP rating) | IP65 |
Approval markings | N.A |
Application | Independent, Class I |
Dimmable (TRIAC、0-10V、DALI、Smart) | N.A |
Dim-off voltage & dim – deep | N.A |
Sensor Type (IR 、Radar、phototonus 、Sound) | N.A |
Isolation (Basic / non-Isolation / SELV) | Basic |
Electric Strength | Input – Output 2500Vac |
EMI | N.A |
Surge (DM / CM) | DM 6kV 、 CM 6kV |
Dimension (L*W*H) &Weight | 112*38*30mm、121g |
Storage Environment | -30~+85℃, 5~80%RH |